Precision air-moving engineering since 2009 Technical support · OEM / ODM · Global supply

Typical Stop Loss Case of Brushless Motor

Typical Stop Loss Case of Brushless Motor

The main failures and analysis are as follows:

I. motor encoder alarm

1. Cause of failure

Wiring error;

Electromagnetic interference;

3. Hardware damage caused by mechanical vibration.

(4) pollution caused by environmental pollution;

2. Troubleshooting

Check wiring and eliminate errors;

(2) Check whether the shield is in place, check whether the wiring is reasonable and solve, if necessary add filter to improve;

Check mechanical structure and improve it;

Check whether the encoders are polluted or corroded (dust, oil dirt, etc.), and strengthen the protection.

3. Installation and wiring standards

(1) use the original cable as far as possible.

(2) separate cables from them as far as possible, especially high pollution wiring.

(3) use internal power as much as possible. If switching power is used, the filter should be used to ensure that the power reaches the cleanliness level.

(4) always connect the public to the ground;

The encoder housing is insulated from the machine structure and connected to the cable shielding layer.

If the encoder can not be insulated, the cable shield layer can be connected to the encoder housing and drive frame grounding (or dedicated terminals).

Two. Broken shaft of motor

1. Cause of failure

(1) unreasonable mechanical design results in excessive radial load.

(2) dead ends or severe transient overload.

3. The motor and reducer are not concentric when assembling.

2. Troubleshooting

(1) check the large radial load capacity of motor samples and improve the mechanical design.

Second, check the operation of the load side, confirm the actual process requirements and improve it.

Check whether the load is stable, whether there is vibration, and improve the accuracy of mechanical assembly.

Three. No load current of motor, unbalanced three-phase.

1. Cause of failure

The winding ends of the winding are wrong.

2. Unbalanced supply voltage;

3. Windings exist inter turn short circuit and coil reverse connection.

2. Troubleshooting

First, check and correct.

Second, measure the power supply voltage and try to eliminate the imbalance.

Eliminate winding fault.

Four. When the motor is running, the noise is abnormal.

1. Cause of failure

(1) bearing wear or foreign particles in oil.

(2) loose core of rotor;

3. Bearing is short of oil.

(4) the supply voltage is too high or unbalanced.

2. Troubleshooting

Replacing bearings or cleaning bearings;

2. Overhaul rotor core;

(3) refueling;

Check and adjust the supply voltage.

Five. The motor is difficult to start. When the load is rated, the speed of the motor is lower than the rated speed.

1. Cause of failure

(1) the power supply voltage is too low.

Secondly, the motor is misconnected by face connection.

3. The rotor is welded or broken.

4. The local coil of the rotor is wrongly connected and reversed.

(3) increasing the number of turns when repairing motor windings;

Motor overload.

2. Troubleshooting

First, measure the power supply voltage and try to improve it.

Second, correct the connection.

Check welding and breakage and repair.

(4) correct the wrong connection.

Correct the number of turns;

Six. The motor can not rotate after electrifying, but it does not smell loudly, nor does it smell and smoke.

1. Cause of failure

(1) the power is not connected (at least two phases fail).

Fuse fuses (at least two phases).

The overcurrent relay is too small.

4. Wrong wiring of control equipment.

2. Troubleshooting

Check whether there is breakpoint in the power circuit switch, fuse and junction box, and repair.

Second, check the fuse type and fuse causes, replace the new fuse.

Adjust the relay setting value to match the motor.

3. Correct wiring.

Seven. The motor vibrates in operation.

1. Cause of failure

Due to excessive wear bearing clearance;

(2) the air gap is uneven.

3. Rotor imbalance;

(4) bending of the rotating shaft;

(5) the coaxality of the coupling (belt pulley) is too low.

2. Troubleshooting

First, repair the bearing and replace it when necessary.

Second, adjust the air gap to make it uniform.

3. Correct rotor dynamic balance.

Straightening the shaft;

(5) recalibrate to make it conform to the regulations.

Previous:

Notice of Holiday Closure

Next:

Understanding Wonsmart Blower Safety Features